Detect hidden electrical faults before they lead to fires, equipment failure or costly downtime with NFPA 70B-compliant electrical infrared inspections for commercial, industrial and critical infrastructure facilities across Dallas-Fort Worth, throughout Texas and nationwide.
30 Years of Industry Experience
Level I, II & III Certified Thermographers
NFPA 70B & NFPA 70E Knowledge
Clear, Prioritized Reporting
Service Overview – From Detection to Action
Electrical failures often develop gradually. Loose connections, overloaded circuits, deteriorating components and abnormal resistance generate heat long before a problem becomes visible. Electrical infrared inspections reveal these hidden thermal anomalies while equipment is energized and operating under normal load.
InfraredTeam provides NFPA 70B-compliant electrical thermography for commercial, industrial and critical infrastructure facilities across Dallas-Fort Worth, throughout Texas and nationwide. Certified thermographers use professional-grade FLIR thermal imaging equipment to inspect electrical distribution systems without interrupting normal operations.
Clear Findings. Prioritized Action. Each inspection is supported by actionable reporting with annotated thermal images, matching digital photographs, temperature data, severity classifications and prioritized recommendations. Critical findings are communicated immediately.
Clear Findings. Prioritized Action. Each inspection is supported by actionable reporting with annotated thermal images, matching digital photographs, temperature data, severity classifications and prioritized recommendations. Critical findings are communicated immediately.
After
Before
Why Electrical Infrared Inspections Matter
Prevent Electrical Fires
Identify overheating connections and components before they become ignition sources.
Reduce Unplanned Downtime
Find deteriorating equipment before it trips, fails or interrupts operations.
Meet NFPA 70B Requirements
Support structured electrical preventive maintenance and required inspection intervals.
Support Insurance Requirements
Provide documentation for insurance audits, risk engineering reviews and coverage requirements.
Extend Equipment Life
Correct developing problems before excessive heat damages adjacent or downstream equipment.
Prioritize Maintenance
Use severity-ranked findings to focus resources on the most urgent corrective actions.
What We Inspect
Electrical Panels
Branch and distribution panels
Switchgear & Switchboards
Main distribution assemblies, lugs and bus connections
Transformers
Connections, terminals and abnormal thermal patterns
Breakers, Fuses & Disconnects
Overheating components and uneven thermal behavior
Motor Control Centers
Buckets, starters, disconnects and terminations
Bus Duct, Transfer & Power Distribution
Bus connections, transfer switches, UPS and generator distribution
What do Electrical Infrared Inspections Reveal?
Loose or Deteriorated Connections
Excessive resistance and localized heating at lugs, terminals and connection points.
Overloaded Circuits
Conductors or components operating near or beyond rated capacity.
Phase Imbalance
Uneven loading in three-phase systems that creates abnormal heating and equipment stress.
Failing Breakers & Fuses
Components running hotter than expected under normal load.
Corrosion & Oxidation
Higher resistance at outdoor, humid or deteriorated connection points.
Internal Equipment Faults
Thermal patterns in transformers, switchgear or bus connections that may indicate degradation.
Findings Severity
Class 1 - No Action
No corrective measure. Data collected for future reference.
Class 2 - As Time Permits
Corrective measures recommended as schedule permits.
Class 3 - Urgent
Corrective measures recommended as soon as possible.
Class 4 – Immediate
Corrective measures recommended immediately.
Inspection Process
1. Plan & Coordinate
Confirm scope, access, operating conditions and site-safety requirements. Equipment should be energized and under sufficient load for meaningful thermal analysis.
2. Inspect
Certified thermographers systematically scan energized panels, switchgear, transformers and other distribution equipment using calibrated professional-grade FLIR cameras.
3. Analyze & Prioritize
Review thermal data and reference images, classify anomalies by severity and communicate urgent findings to on-site personnel immediately.
4. Report
Deliver annotated thermal and visual images, temperature data, component identification and prioritized recommendations, typically within 3-5 business days.
Flexible Service Models
Full Service
InfraredTeam supplies the certified thermographer and electrician.
EC-Supplied
The client or electrical contractor supplies the electrician; InfraredTeam provides independent thermography.
White Label
Independent thermography and reporting for electrical contractor partners when appropriate.
Industries Served
Electrical infrared inspections support facilities where reliability, electrical safety, uptime and documented preventive maintenance are critical.
Data Centers
Hospitals & Healthcare Systems
Industrial Plants & Manufacturers
Refineries & Energy Facilities
Military Bases & Government Facilities
Airports & Transportation Hubs
Apartments & Multi-Family Housing
Hotels & Hospitality Groups
Real Estate Developers & Property Managers
Why Choose InfraredTeam for Electrical Thermography?
- Independent & Unbiased Analysis: We provide objective thermal inspections and diagnostics—never tied to repair upsells or third-party vendors
- Continual Investment in Technology & Training: We use industry-leading infrared cameras and software, and our team stays current with NFPA, drone, and certification standards
- Fast Turnaround & Clear Reporting: Receive annotated, prioritized reports within days, so you can take immediate action and reduce downtime risk.
- NFPA 70B / 70E Compliance Focus: We help facilities meet thermal inspection requirements for preventive maintenance, electrical safety, and risk mitigation.
- Texas-Based with Nationwide Reach: Headquartered in the Dallas–Fort Worth Metroplex, we serve clients statewide and across the US—supporting single and multi-site operations.
- ROI-Driven Recommendations: Our inspections highlight the most critical findings so you can prioritize actions that deliver the greatest return on investment.
Featured Field Result
Extreme Overheating Identified at Food Processing Plant
During an inspection at a food processing plant, InfraredTeam identified one phase of a motor control center operating at more than 536°F, with the wire insulation melted off.
The plant shut down, the breaker and wire were replaced, and they were back up and running in approximately two hours.
Finding: One phase of a motor control center operating above 536°F with melted wire insulation.
Action: Plant shut down; breaker and wire replaced.
Outcome: Back up and running in approximately two hours.
The plant shut down, the breaker and wire were replaced, and they were back up and running in approximately two hours.
Finding: One phase of a motor control center operating above 536°F with melted wire insulation.
Action: Plant shut down; breaker and wire replaced.
Outcome: Back up and running in approximately two hours.
FAQs
How often should electrical infrared inspections be performed?
NFPA 70B (2023) sets infrared inspection intervals by equipment condition, typically every 12 months and every 6 months for equipment in poor condition or harsh environments
Does the equipment need to be shut down?
No. Electrical equipment generally needs to be energized and operating under load so thermal imaging can identify meaningful temperature differences and developing faults.
What is included in the report?
Reports include annotated thermal images, matching digital reference photos, temperature and delta-T data, component identification, severity classifications and prioritized recommendations.
How quickly will we receive the report?
Typical report delivery is within 3-5 business days. Urgent findings are communicated to on-site personnel immediately.
Can the report support insurance and compliance requirements?
Yes. InfraredTeam reports are designed to support NFPA 70B documentation, insurance audits and risk-management programs. Specific requirements and acceptance may vary by insurer or organization.
Related Services
Build a Stronger Electrical Reliability Program
Mechanical Systems Thermography
Monitor motors, bearings, pumps, and equipment to prevent downtime and extend operational life.
Roof & Moisture Intrusion Surveys
Identify roof leaks, moisture ingress, and insulation voids with aerial or handheld imaging.
Drone / Aerial Infrared Imaging
Cover large-scale roofs, solar panels, and industrial campuses with high-resolution thermal flyovers.
Arc Flash Studies
Support electrical safety planning with PE-sealed arc flash studies, hazard analysis and equipment-specific labeling
Protect your Electrical Systems Before A Small Problem Becomes A Major Failure
Schedule an NFPA 70B-compliant electrical infrared inspection for a single facility or a nationwide multi-site program.